Mfg Part Number: 300073 | NSN : 5950-01-056-7683 | NIIN : 010567683 |
CAGE Code : 21793 | Manufacturer: Astronics Test Systems Inc | Item Name : Transformer Power |
FSC : 5950 Coils and Transformers |
Thank you for choosing Aircraft Parts Supplier for all your operational needs. You have reached our NSN RFQ Page which features our in-demand NSN 5950-01-056-7683 parts and components such as Transformer Power manufactured by Astronics Test Systems Inc. Some of these items include part number 300073, and various others, all of which have been subjected to a number of quality assurance measures, tests, verifications, and assessments. At Aircraft Parts Supplier, we make it our priority to only source from top global manufacturers that we trust, assuaging the worry of not receiving quality items from us.
The part 300073 with NSN 5950-01-056-7683 that we feature by the manufacturer Astronics Test Systems Inc are paired alongside CAGE Code 21793 is available and readt to ship. Aircraft Parts Supplier carries a variety of NSN products, allowing us to be the go-to supplier for countless businesses. If you are familiar with the NSN associated with the item you are in search of, we invite you to take advantage of it. Similarly, other information regarding the NSN items you wish to purchase is equally as helpful, so please provide such details in the provided RFQ form below. When you fill out a form, in return, you will be provided a competitive quote for your comparisons in just 15 minutes or less.
NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
---|---|---|---|---|---|---|
5950-01-056-7683 Item Description: Transformer Power | 5950 | 010567683 | 0 | P | ||
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
U | U | |||||
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
300073 | 6 | 2 | 3 |
MRC | Criteria | Characteristic |
---|---|---|
AARG | RELIABILITY INDICATOR | NOT ESTABLISHED |
ABKQ | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | 2.188 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
ABKR | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH | 1.750 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
ABTB | MOUNTING HOLE DIAMETER | 0.250 INCHES NOMINAL SINGLE GROUP |
ACZB | FREQUENCY RATING | 60.0 HERTZ NOMINAL SINGLE COMPONENT |
ACZC | INPUT-OUTPUT PHASE RELATIONSHIP | SINGLE PHASE TO SINGLE PHASE SINGLE COMPONENT |
ACZX | WINDING SHIELDING METHOD | INTERNAL SHIELD GROUNDED TO INCLOSURE AND BROUGHT OUT TO TERMINAL SINGLE COMPONENT |
ADAQ | BODY LENGTH | 2.630 INCHES NOMINAL |
ADAT | BODY WIDTH | 2.190 INCHES NOMINAL |
ADAU | BODY HEIGHT | 3.600 INCHES NOMINAL |
AKNA | INCLOSURE TYPE | PARTIALLY INCLOSED, HALF SHELL |
AKPV | MOUNTING FACILITY QUANTITY | 4 SINGLE GROUP |
AXGY | MOUNTING METHOD | FLANGE SINGLE GROUP AND UNTHREADED HOLE SINGLE GROUP |
BPLC | WINDING FUNCTION AND QUANTITY | 2 PRIMARY SINGLE COMPONENT AND 2 SECONDARY SINGLE COMPONENT |
CRBZ | WINDING OPERATING CURRENT | 12.0 MILLIAMPERES AC MINIMUM SINGLE COMPONENT 1ST SECONDARY |
CRBZ | WINDING OPERATING CURRENT | 250.0 MILLIAMPERES AC MAXIMUM SINGLE COMPONENT 2ND SECONDARY |
CWJS | WINDING OPERATING VOLTAGE | 100.00 AC VOLTS NOMINAL SINGLE COMPONENT ALL PRIMARY AND 115.00 AC VOLTS NOMINAL SINGLE COMPONENT ALL PRIMARY AND 120.00 AC VOLTS NOMINAL SINGLE COMPONENT ALL PRIMARY |
TTQY | TERMINAL TYPE AND QUANTITY | 18 WIRE LEAD |
![]() |